Why ferrite testing is ordered
Ferrite content in stainless weld metal controls two things. Too little ferrite in an austenitic weld raises the risk of hot cracking, and too much in a duplex weld lowers toughness and corrosion resistance. Specifications for duplex and super duplex piping, pressure vessels and subsea parts often set a ferrite range, commonly measured as ferrite number or percent ferrite. Owners order testing to accept welds before hydrotest or to qualify a welding procedure. Welding procedure and filler requirements come from the code or project specification, and the American Welding Society publishes the ferrite measurement practice most specifications cite at aws.org.
How ferrite testing is billed
| Service | How it is usually billed | Illustrative planning range |
|---|---|---|
| Field readings with a calibrated ferrite meter | Per inspector day, readings included | $900 to $1,600 per day |
| Lab ferrite measurement on weld coupons | Per coupon or per sample | $120 to $300 per sample |
| Metallographic point count (percent ferrite) | Per specimen, includes polishing and etching | $250 to $600 per specimen |
| Procedure qualification package with ferrite | Per procedure, bundled with other tests | Added line on a PQR budget |
| Report | Per report or included | $100 to $350 |
Mobilization, travel and a minimum charge apply on small jobs. A magnetic ferrite meter is quick on a weld you can reach, while a point count is the reference method and needs a cut specimen. If the same job also needs a material check on filler or pipe, see PMI testing cost and positive material identification services.
Worked example, 40 duplex piping welds
Assume a duplex stainless process line with 40 butt welds, each measured at three points on the cap, plus two qualification coupons with a point count. These inputs are assumed for the example.
| Line | Quantity | Planning figure |
|---|---|---|
| Field survey, 120 readings at about 25 per hour | 5 hours, one day minimum | $1,100 |
| Mobilization and travel within the region | 1 | $350 |
| Point count on 2 procedure coupons | 2 specimens | $900 |
| Report with weld map and readings | 1 | $250 |
| Total | about $2,600 |
That works out to roughly $65 per weld. If the owner books ferrite readings during a visual weld inspection visit, the day rate is shared and the field line drops. See visual weld inspection services and pipe weld inspection for combining scopes.
What moves the price up or down
- Number of welds and readings per weld. Specs that ask for several points per weld multiply the hours.
- Access. Scaffold, insulation removal and welds in tight skids slow the work.
- Surface preparation. Meter readings need a clean, ground surface, and heat tint must be removed first.
- Reference method. A point count on cut specimens costs more than meter readings.
- Reporting and calibration. Some owners want calibration certificates traced to standards, which adds a line.
Who should read this, and who should not
This guide fits fabricators, EPC quality managers and plant owners who must budget ferrite acceptance on stainless, duplex or super duplex welds. It does not help if you want to buy a ferrite meter, since the numbers are service rates. If your question is about weld flaws rather than ferrite content, look at ultrasonic testing services or radiographic testing cost.
How to get comparable quotes
- State the alloy, the pipe or vessel size, and the weld count.
- Give the acceptance range and the standard or specification it comes from.
- Say how many readings per weld and where, for example cap and root side.
- Say if the work happens at your shop, in the field or on a lab coupon.
- Ask each company to price mobilization, readings and report as separate lines.
You can send one request to several companies through the NDT companies directory, and the NDT inspection cost guide shows how other methods compare.
How much does ferrite testing cost?
Field ferrite readings often run about $900 to $1,600 per inspector day, and lab point counts run roughly $250 to $600 per specimen. A 40 weld duplex line is commonly around $1,500 to $3,500 with a report. Mobilization and access change the total more than the readings.
What is ferrite testing?
Ferrite testing measures the ferrite content of weld metal in stainless and duplex steels, reported as ferrite number or percent. It is done with a calibrated magnetic meter in the field or with a metallographic point count in a lab. Specifications set the acceptable range.
Is ferrite testing destructive?
Meter readings are not destructive, they only need a clean surface. A metallographic point count needs a cut and polished specimen, so it is used on coupons or removed samples. Many jobs use meter readings on production welds and point counts to qualify the procedure.
Who performs ferrite testing?
Welding inspection firms, materials testing labs and some NDT companies perform it. Ask for the inspector's training record and the meter calibration. One request through the NDT companies page lets you compare several.