Skip to content
IndustrialImaging

API 579 fitness for service inspection data and flaw sizing

IndustrialImaging helps you get the inspection data an API 579 fitness for service assessment runs on. A fitness for service study decides whether a vessel, pipe or tank with a known flaw can keep running, and the engineer doing it needs measured numbers: remaining wall on a grid, crack height and length, pit depth and profile. Describe the flaw and the assessment level once, and the request goes to NDT companies that size flaws and write reports an engineer can use.

API 579 fitness for service inspection data and flaw sizing
01

What data an API 579 assessment needs from inspection

Flaw or damageWhat the assessment needsNDT method that supplies itTypical report output
General or local metal loss Thickness readings on a grid, minimum measured thickness, extent Ultrasonic thickness testing, automated corrosion mapping Grid map with minimum, average and the critical thickness profile
Pitting Pit depth, density and the deepest pit in each area UT, laser or profile gauge after cleaning Pit chart with depth and spacing
Cracks and crack like flaws Through wall height and length, orientation, surface or embedded Phased array and TOFD, with magnetic particle to find the surface length Flaw sheet with height, length and position
Laminations, blisters and hydrogen damage Size and depth of the planar flaw UT scanning Plan view map of the affected area
Dents, gouges and weld misalignment Depth, profile and distance to welds Laser scan, contact profile, UT Profile data and sketch
Long term wall loss rate Two thickness surveys at the same points Repeat UT on fixed points Corrosion rate per point

The inspection company measures and reports. It does not decide the equipment is fit. That judgment belongs to the engineer who runs the assessment, and the data only helps if it is in the form the engineer asked for.

02

Where the assessment procedure comes from

Fitness for service of pressure equipment is set out in API 579-1/ASME FFS-1, which defines three assessment levels. Level 1 uses simple screening with limited data, Level 2 calculations need detailed measurements, and Level 3 usually involves finite element analysis and the most complete flaw data. The higher the level, the more precise the inspection has to be, so ask the engineer which level applies before the crew mobilizes. Equipment still under an inspection code is often governed by API 510 for vessels or API 570 for piping.

03

Who buys inspection for fitness for service

  • Plant engineers who found wall loss on a vessel or pipe below the retirement thickness and need data to justify continued operation.
  • Reliability managers facing a turnaround deadline with a flaw found by UT scanning, where replacement would cost weeks.
  • Owners with a crack like flaw reported by a weld inspection who must size it before deciding repair or run.
  • Engineering firms that run FFS studies and need subcontract crews with automated UT, PAUT and TOFD for the data collection.
  • Tank and pipeline operators with dents or corrosion clusters found in an inline or floor survey.
04

How a fitness for service inspection job runs

  1. You describe the equipment, the flaw already found and how it was found.
  2. You name the assessment level and attach any data request from the FFS engineer, such as grid spacing.
  3. The company confirms the method and the resolution it can achieve on your material and thickness.
  4. The crew cleans the area, marks the grid and collects the readings, with calibration records.
  5. You receive raw data and a report with maps, minimum values and flaw dimensions that the engineer can load into the assessment.
05

What drives the price of FFS inspection data

  • Grid density. A 1 inch grid costs many times more than a 6 inch grid on the same patch, so confirm what the engineer really needs.
  • Method. Manual grid readings cost less per area but automated scanning gives denser data and a record that supports a Level 2 study.
  • Surface preparation. Insulation removal, scaffold and cleaning are often larger than the measurement itself.
  • Flaw sizing technique. PAUT and TOFD cost more per day than thickness gauging but are what a crack height measurement needs.
  • Repeat surveys. A corrosion rate needs a second set of readings on the same points, priced as a separate visit.

For typical ranges see ultrasonic testing cost and pressure vessel inspection cost.

06

What to put in your fitness for service inspection request

RFQ
Draft
  • 01Equipment type, material, design pressure and temperature, nominal and measured thickness.
  • 02The flaw found, where, how it was found and any earlier readings.
  • 03Assessment level and the person or firm doing the assessment.
  • 04Grid spacing, flaw dimensions and data format the engineer asked for.
  • 05Surface condition, insulation, access and the turnaround or shutdown window.
  • 06Whether a rate comparison with older data is needed.
07

How to choose a company for FFS inspection data

Ask which technique the company will use for sizing and what accuracy it achieves on your thickness. Crack height needs a qualified PAUT or TOFD procedure and a technician who has sized similar flaws, not only a thickness gauge operator. Confirm the report contains raw readings and location references, not only a summary, because the assessing engineer must check the data. Compare quotes that price preparation, scanning, retest and reporting as separate lines.

08

Who this page is for, and who it is not for

It fits owners and engineers who already have a flaw and need measurements to support a run, repair or replace decision. It does not replace the engineering assessment itself, which requires a qualified engineer with the design data. If you only need a routine inspection with no known flaw, start with pressure vessel inspection services or piping inspection services.

09

FAQ

What is API 579 fitness for service?

API 579-1/ASME FFS-1 is the standard that sets out how to assess whether equipment with a known flaw can stay in service. It covers metal loss, cracks, pitting, dents and more. The assessment uses measured flaw data, so the inspection that supplies it must meet the resolution the engineer specifies.

What inspection data is needed for a fitness for service assessment?

It needs the flaw dimensions and the remaining wall around it: thickness on a grid, pit depth, crack height and length, and location relative to welds. Material, operating conditions and past readings are also needed. The assessing engineer states the exact grid and format.

Can a UT inspection company perform the fitness for service assessment?

Most inspection companies measure and report only. The assessment is an engineering calculation signed by a qualified engineer, often at a separate firm. Some companies have engineers in house, so ask when you request quotes.

How much does inspection for a fitness for service study cost?

It depends on grid density, preparation, method and the number of visits, and a simple patch can be a one day job while a full vessel is several days. A request through the advisor returns quotes for your own equipment on one scope.

Does a fitness for service assessment replace repair?

No. It shows whether equipment can run safely to a set date or condition, often with a re-inspection interval. Many owners use it to defer a repair to the next turnaround.

Get matched with companies that size flaws

Open the inspection method advisor, enter the equipment, the flaw and the assessment level, and it builds a request for quote for NDT companies in your region. You compare quotes on one scope instead of describing the flaw to each company. Browse every method on the NDT companies page.

Inspection request sheet
01What needs inspecting
...
02Material
...
04Concern
...

Run an NDT company? List your company

Show your automated UT, PAUT and TOFD crews and the states you cover, and receive fitness for service data requests that fit your equipment and certifications. Learn more for providers.